12L NG/LPG DP – 12 FV __ 16L NG ETL __ 16L LPG ETL
We carry the Z-Flex vent pipe.
For tankless water heaters, it is single walled for models like the 12L NG DP – 12 FV, the 16L NG ETL and the 16L LPG ETL.
Stainless Steel Z-Vent Wall Hung Water Heater Vent Kit For 12L NG DP – 12 FV, the 16L NG ETL and the 16L LPG ETL.
(1) ___ 3″ Rain Cap
(1) ___ 3″ Top Support/Storm Collar
(1) ___ 3″ Adjustable Roof Flashing (normal 30 degree flashing)
(1) ___ 3″ Universal Appliance Adaptor
(1) ___ 3″ Back Flow Preventor
(1) ___ 3″ Vertical Drain Pipe
You will need to determine how many additional feet you will need as well determine if you will need a condensation drain.
There is a maximum vent run of 20 feet, subtracting 4 feet for every 90 degree elbow in the run.
Just so you know ANY Vertical Venting Installation with more than a 5′ run length requires a vertical condensation drain pipe as well.
Please NOTE : A Termination Hood Or Straight Pipe Section Must Be Equipped With A Damper/Backflow Preventer Is Mandatory To Ensure That Freezing Air Does Not Come Back Down Through The Vent Stack.
This May Cause Freeze Damage Internally In The Water Heater And Is Not Covered Under Warranty.